Description: Binds to MT-MMP. No cross reactivity with other MMP family members (MMP-1, MMP-2, MMP-3, MMP-9).
Primary Antibody
Name: MT1-MMP-2 (MMP-14) Antibody |
Clone: Rabbit polyclonal |
Supplier: Chemicon |
Catalog Number: AB815 |
Dilution: 1:250 using IHC-TekTM Antibody Diluent (Cat# IW-1000 or IW-1001) to reduce background and unspecific staining and serum blocking step is NOT needed. |
Incubation Time/Temp: 60 min/room temperature |
Device: IHC-TekTM Epitope Retrieval Steamer Set (Cat# IW-1102) |
Buffer/pH value: IHC-TekTM Epitope Retrieval Solution (Cat# IW-1100) |
Heat/Cool Temperature: 95-100 ºC/room temperature |
Heat/Cool Time: 20 minutes/20 minutes |
Standard Method: ABC Method or LSAB Method |
Enhanced Method: Polymeric Methods |
Reagent: DAB |
Incubation Time/Temperature: 1-3 minutes/room temperature |
Reagent: Mayer's Hematoxylin |
Staining Time: 30 seconds |
Staining Pattern: Cytoplasmic |
Images: Search image |
Tissue Type: Heart |
Fixation: Formalin fixed paraffin sections |
Positive Control: Heart |
Negative Control: Omit primary antibody, isotype control, absorption control |
Blocking: 2-5% normal serum to reduce unspecific background staining; 0.5-3% H2O2 to block endogenous peroxidase activity; avidin/biotin to block endogenous biotin activity if necessary |
References: